Yutaki-S80

Enquire Now

Hitachi’s Yutaki-S80 high temperature heat pump generates hot water up to 80°C and is ideal as a boiler replacement for heating and domestic hot water.

The system utilises an energy-efficient, secondary Cascade R134a Heat Pump Circuit instead of an electrical element to provide a boost from 45°C to 80°C.

This allows the home-owner or business to benefit from cost savings generated from using Heat Pump and Inverter technology at higher temperatures.

Year-round comfort, with heat output available at ambient temperatures as low as -20°C.

Indoor Unit ModelRWH4.0(v)NFERWH5.0(v)NFERWH6.0(v)NFE
Outdoor Unit ModelRAS-4WH(V)NPERAS-5WH(V)NPERAS-6WH(v)NPE
Nominal Capacity (max)kW11.00 (15.20)14.00 (16.70)16.00 (17.80)
Water 30/35°C, Ambient 7db/6wb°CCOP54.714.57
Nominal Capacity (max)kW11.00 (14.50)14.00 (17.00)16.00 (18.00)
Water 40/45°C, Ambient 7db/6wb°CCOP3.93.783.6
Nominal Capacity (max)kW11.00 (14.50)14.00 (17.00)16.00 (18.00)
Water 47/55°C, Ambient 7db/6wb°CCOP3.323.193.1
Nominal Capacity (max)kW11.00 (14.50)14.00 (17.00)16.00 (18.00)
Water 30/35°C, Ambient 2db/1wb°CCOP2.93.193.1
Nominal Capacity (max)kW9.70 (10.60)11.50 (12.20)12.10 (13.00)
Water 30/35°C, Ambient -7db/-8wb°CCOP2.742.652.57
Nominal Capacity (max)kW11.00 (12.50)14.00 (14.50)16.00 (16.00)
Water 40/45°C, Ambient -7db/-8wb°CCOP2.42.32.2
Nominal Capacity (max)kW11.00 (12.50)14.00 (14.50)16.00 (16.00)
Water 47/55°C, Ambient -7db/-8wb°CCOP2.32.22.06
Nominal Capacity (max)kW11.00 (12.50)14.00 (14.50)16.00 (16.00)
Water 47/55°C, Ambient -7db/-8wb°CCOP2.12.051.95
RefridgerationR134A
Water Flow Rate min/maxm3/hr1.0 / 2.81.1 / 3.21.2 / 3.2
Minimum Water Volume (Defrost)L4050
Water ConnectionsInch1 1/4 Female
Expansion Vessel SizeL12.00
Pump TypeYonos PARA RS 15 / 7.5
Water Temperature Range°C20 - 80
Piping Diameter (liquid/gas)Inch3/8" / 5/8"
Power Supply230V/1Ph/50Hz + 400V/3Ph/50Hz
Circuit Breaker SizeA32 / 16
Maximum Operating CurrentA24.3 / 15.328.3 / 15.331.3 / 15.3
Sound Power LeveldB(A)57.0058.00
Dimensions (H x W x D) Including Connectionsmm800 x 600 x 623
Gross WeightKg146 / 149149 / 152

Outdoor unit ModelRAS 4 WH(V)NPRAS 5WH(V)NPRAS 6WH(V)NP
RefridgerantR410A
Minimum Piping Lengthm5
Maximum Chargeless Piping Lengthm15
Piping Diameter (liquis/gas)Inch3/8" / 5/8"1/4" / 1/2"
Maximum Piping Lengthm75
Additional Refrigerant Chargeg (per metre)60
Power Supply230V/1Ph/50Hz + 400V/3Ph/50Hz
Circuit Breaker Size ( Single / Three Phase)A32 / 16
Maximum Operating CurrentA30.5 / 1430.5/ 16
Sound Power Level @ 7/35 *dB(A)636465
Dimentions (H x W x D)mm1380 x 950 x 370
Gross WeightKG116
Compressor TypemmScroll DC Inverter Driven
* Sound power level in accordance to the standard EN 12102 at conditions specified in EN 14511 performance test

Features and Benefits:
Domestic hot water as well as heating – ideal boiler replacement technology
Two heating circuits
Capacities: 11kW, 14kW and 16kW
Easy to install, operate and service
Hot water recovery time same as a DHW boiler
Smart Cascade system for outstanding seasonal energy efficiency
Weather compensation control
Generate water up to 80°C
DHW legionella protection program
One of the best COP’s on the market up to 5.00
ErP energy efficiency class of up to A+++

Remote Controller PC-ARFHE (Includes; weekly timer, holiday mode, smart function and a favourite button)
Wireless Remote Thermostat ATW-RTU-05 (Control remotely via smartphone app)
Optional domestic hot water tank and buffer tanks
Available from 11 to 16 kW, single and three phase models available

 

Advanced Technical Data

Outdoor Unit ModelRASM-3VNERASM-4(V)NERASM-5(V)NERASM-6(V)NE
Nominal Capacity (max)kW7.50 (11.00)11.00 (15.20)14.00 (16.70)16.00 (17.80)
Water 30/35°C, Ambient 7db/6wb°CCOP4.555.004.714.57
Nominal Capacity (max)kW7.50 (10.00)11.00 (14.10)14.00 (15.70)16.00 (17.30)
Water 40/45°C, Ambient 7db/6wb°CCOP3.503.803.613.40
Nominal Capacity (max)kW7.50 (9.20)11.00 (13.50)14.00 (15.20)16.00 (17.00)
Water 47/55°C, Ambient 7db/6wb°CCOP2.703.002.802.50
Nominal Capacity (max)kW5.50 (8.90)9.50 (12.80)10.50 (13.90)11.10 (15.00)
Water 30/35°C, Ambient 2db/1wb°CCOP3.533.703.553.41
Nominal Capacity (max)kW5.80 (6.70)9.70 (10.60)11.50 (12.00)12.00 (13.00)
Water 30/35°C, Ambient -7db/-8wb°CCOP2.572.742.652.57
Nominal Capacity (max)kW6.00 (6.40)10.00 (10.00)11.00 (11.60)11.50 (1250
Water 40/45°C, Ambient -7db/-8wb°CCOP2.252.452.252.15
Nominal Capacity (max)kW5.00 (5.50)8.70 (9.70)9.70 (11.20)10.50 (12.00)
Water 47/55°C, Ambient -7db/-8wb°CCOP1.721.781.851.75
Water Flow Rate min/maxm3/hr0.60 / 2.101.00 / 2.801.10 / 3.001.20 / 3.00
Minimum Water Volume (Defrost)L28384655
Water ConnectionsInch1 1/4 Female
Expansion Vessel SizeL6
Pump TypeYonosPARARS15/7.0Yonos PARA RS 15 / 7.5
Water Temperature Range°C20 - 5520 - 60
Power Supply230V/1Ph/50Hz230V/1Ph/50Hz + 400C/3PH/50Hz
Circuit Breaker Size (with DHW tank heater)A3250 / 32
Circuit Breaker Size (without DHW tank heater)A2032 / 20
Maximum Operating Current (with DHW tank heater)A3345.80 / 30.0045.80 / 39.40
Maximum Operating Current (without DHW tank heater)A1830.8
Sound Power Level @7/35 *dB(A)61636465
Dimensions (H x W x D) Including Connectionsmm800 x 1252 x 3701380 x 1252 x 370
Gross WeightKg115135140144
Back to products