R32 PZH2 Big PAC-i Elite Condensing Units for Single to Quad Application

Enquire Now

Panasonic PZ2  Elite Condensing units allow connectivity for larger Ducted Systems (20kW and 25kW) for larger warehouses and retail applications. 

These condensing units also allow connectivity for Twin, Triple and Quad Combinations allowing flexibility of installation for Cassettes, Ducted, Under Ceiling and Wall Mounted Fan Coils in large retail and commercial office applications.

Ideal also for Air Handling Unit applications in Warehouses (High ESP), Hospitals and Shopping Centres, allowing multiple DX coil connections (example 4 x 25kW AHU Coil Circuit) and simple connectivity with BMS. 

Outdoor Unit Technical Data
ModelU-200PZH2E8U-250PZH2E8
CombinationsTwin/Triple/Quad
Height (mm)15001500
Width (mm)980980
Depth (mm)370370
Weight (kG)117128
Airflow (l/sec) Cool/Heat2733 / 27332667 / 2667
Sound Pressure Cooling (dBA)5959
Sound Pressure Heating (dBA)6163
Liquid (mm(inches))1 1/81 1/8
Gas (mm(inches))3/81/2
Max Pipe Run (m)9090
Max Pipe Lift (m)3030
Pre-charged to (m)3030
Standing Charge (kG)4.25.8
Additional Charge per meter (g)6080
RefrigerantR32
PhaseThree
Power Supply toIU (5A) and OU or OU with feed to IU
Running Current (Cool - Heat)TBCTBC
Input Power (Cool - Heat)6.06 / 6.217.46 / 8.21
Fuse Rating (A)3232
Interconnecting2C Screen 0.75mm?
Twin Pipe KitCZ-P680BK2BM
Triple Pipe KitCZ-P3HPC2BMNo Combination
Quad Pipe CombinationCZ-P680BK2BM x 1 and CZ-P224BK2BM x 2

 

Compatible products

 

Features and Benefits

  • Auto restart after power failure
  • Auto changeover
  • Twin, triple and double-twin split options
  • PAC-i Elite Seasonal Inverter
  • ErP Compliant
  • Cooling to -15°C
  • Heating to -20°C
  • R22 Replacement Technology

Power/Wiring

PZ2 (20 and 25kW) Models only

Panasonic PZ2 PAC-i systems require a separate power supply to Indoor (3 Amp isolator for all units) and Outdoor Units. It is also possible to supply power to outdoor unit only, and run power to indoor via a 3 core flex from a field supplied inline fuse. Please click here for further information. A separate 2 core 0.75mm² screened cable will also be required for data connection

Three Phase Triple Split example

Piping

CZ-P224BK2BM Pipe Kit required for s PAC-i Elite Triple and Quad Split installations up to 25kW (used with CZ-P680 combination – check with Logicool for final combinatation)

CZ-P680BK2BM Pipe Kit required for all PAC-i Elite Twin Split installations 20kW to 25kW

CZ-P3HPC2BM Pipe Kit required for all PAC-i Elite Triple Split installations up to 10kW to 25kW

 

 

Back to products
Add selected to wishlist