Panasonic Free Multi systems are the best choice to bring comfort to your
whole home or office. One compact, single unit can connect with up to
five indoor units, saving space outside. Each room will have independent
control so occupants can enjoy more precise temperature control and
energy savings when the room is not in use. New generation refrigerant
R32 allows excellent performance credentials, achieving A+++ and
minimizing the environmental impact.
Model Reference | Nom. Cool (kW) | Nom. Heat (kW) | Max Pipe (m) per Leg | EuP Lot 10 Energy Rating | Fuse Amps) | I/C Cable (Core) | Pipe Sizes | Max Pipe (m) | Electrical Supply |
||
(Min/Max) I/U Conn. | Outdoor Unit Reference | SCOP | SEER | ||||||||
2-2 | CU-2Z35TBE | 3.50 | 4.20 | 20 | SCOP and SEER dependant on system combination. Please contact Logicool | 16 | 3C + E Per Indoor Unit Power fed from Outdoor Unit | As per Indoor Unit table. Check config. with Install Manual | 30 | Single | |
2-2 | CU-2Z41TBE | 4.10 | 4.60 | 20 | 16 | 30 | Single | ||||
2-2 | CU-2Z50TBE | 5.00 | 5.60 | 20 | 16 | 30 | Single | ||||
2-3 | CU-3Z52TBE | 5.20 | 6.80 | 25 | 16 | 50 | Single | ||||
2-3 | CU-3Z68TBE | 6.80 | 8.50 | 25 | 16 | 60 | Single | ||||
2-4 | CU-4Z68TBE | 6.80 | 8.50 | 25 | 20 | 60 | Single | ||||
2-4 | CU-4Z80TBE | 8.00 | 9.40 | 25 | 20 | 70 | Single | ||||
2-5 | CU-5Z90TBE | 9.00 | 10.40 | 25 | 25 | 80 | Single |
Features and Benefits
Advanced Technical Data
Outdoor Unit Technical Data | ||||||||
Model | CU-2Z35TBE | CU-2Z41TBE | CU-2Z50TBE | CU-3Z52TBE | CU-3Z68TBE | CU-4Z68TBE | CU-4Z80TBE | CU-5Z90TBE |
Cooling Capacity (Nom. Min-Max) - kW | 3.50 (1.5 - 4.50) | 4.10 (1.50 - 5.20) | 5.00 (1.50 - 5.40) | 5.20 (1.80 - 7.30) | 6.80 (1.90 - 8.00) | 6.80 (1.90 - 8.80) | 8.00 (3.00 - 9.20) | 9.00 (2.90 - 11.50) |
EER | 4.86 (6.00 - 4.09) | 4.56 (6.00 - 3.8) | 4.42 (6.00 - 3.62) | 4.77 | 3.66 (7.04 - 3.38) | 4.39 (5.59 - 3.56) | 4.04 (5.66 - 3.21) | 4.09 (5.27 - 2.98) |
SEER | 8.5 | 8.5 | 8.5 | 8.5 | 8 | 8 | 7.9 | 8.5 |
Pdesign (Cooling) kW | 3.5 | 4.1 | 5 | 5.2 | 6.8 | 6.8 | 8 | 9 |
Input Power Cooling (Nom. min-max) kW | 0.72 (0.25 - 1.10) | 0.90 (0.25 - 1.37) | 1.18 (0.25 - 1.49) | 1.09 (0.36 - 2.18) | 1.86 (0.27 - 2.37) | 1.55 (0.34 - 2.47) | 1.98 (0.53 - 2.87) | 2.20 (0.55 - 3.86) |
Annual Electricity Consumption (cooling) kWh/a | 144 | 169 | 206 | 214 | 298 | 298 | 990 | 1100 |
Heating Capacity (Nom. Min-Max) kW | 4.20 (1.10 - 5.60) | 4.60 (1.10 - 7.00) | 5.60 (1.10 - 7.00) | 6.80 (1.60 - 8.30) | 8.50 (3.30 - 10.40) | 8.50 (3.00 - 10.60) | 9.40 (4.20 - 10.60) | 10.40 (3.40 - 14.50) |
Heating Capacity at -7°C - kW | - | 3.95 | 4.45 | 4.45 | ||||
COP | 4.88 (5.24 - 4.18) | 4.79 (5.24 - 3.91) | 4.63 (5.24 - 4.00) | 4.72 | 3.95 (5.32 - 3.64) | 4.47 (5.17 - 3.96) | 4.63 (6.00 - 3.46) | 4.84 (6.42 - 3.42) |
SCOP | 4.6 | 4.6 | 4.6 | 4.2 | 4.2 | 4.2 | 4.7 | 4.68 |
Pdesign at -10°C - kW | 3.2 | 3.5 | 4.2 | 5 | 5.2 | 5.2 | 6.8 | 8.5 |
Input Power Heating - kW | 0.86 (0.21 - 1.34) | 0.96 (0.21 - 1.79) | 1.21 (0.21 - 1.80) | 1.47 (3.20 - 2.17) | 2.15 (0.62 - 2.86) | 2.15 (0.62 - 2.86) | 2.03 (0.70 - 3.06) | 2.15 (0.53 - 4.24) |
Annual Electricity Consumption (Heating) - kWh/a | 974 | 1065 | 1278 | 1667 | 1733 | 1933 | 3036 | 2543 |
Current (Cool/Heat) - Amps | 3.35 / 4.00 | 4.15 / 4.45 | 5.35 / 5.50 | 5.30 / 6.70 | 8.40 / 9.70 | 7.00 / 8.60 | 9.50 / 9.50 | 10.50 / 10.10 |
Power Source - V/Hz/Ph | 230/1/50 | |||||||
Recommended Fuse - Amps | 16 | 16 | 16 | 20 | 20 | 25 | ||
Recommended Power Cable - mm² | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 3.5 |
Sound Pressure (Cool/Heat) - dBA | 48 / 50 | 48 / 50 | 50 / 52 | 47 / 48 | 51 / 52 | 49 / 50 | 51 / 52 | 53 / 54 |
Height - mm | 619 | 795 | 999 | |||||
Width - mm | 824 | 875 | 940 | |||||
Depth - mm | 299 | 320 | 340 | |||||
Nett Weight - kG | 39 | 71 | 71 | 72 | 80 | 81 | ||
Liquid - inches | 1/4 (6.35mm) | |||||||
Gas - inches | 3/8 (9.52mm) | |||||||
Max Height Difference - m | 10 | 15 | 15 | 15 | 15 | |||
Piping Length Total - m | 6m - 30m | 6m - 50m | 6m - 60m | 6m - 70m | 6m - 80m | |||
Max Pipe per Unit - m | 3m - 20m | 3m - 25m | 3m - 25m | 3m - 25m | 3m - 25m | |||
Refrigerant | R32 | |||||||
Refrigerant Charge (kG) | R32 | Pending | 2.72 | 2.72 | ||||
Pre-Charged to - m | 20 | 45 | ||||||
Additional Refrigerant Charge - m | 15 | 20 | ||||||
Operating Range - Cooling - °C | -10 to +46 | |||||||
Operating Range - Heating - °C | -15 to +24 |