High Static PF1 Concealed Duct (R32)

Enquire Now

Be ready for the future, the new generation of Panasonic Heating and cooling systems are designed to optimize the operation with R32 refrigerant.

The new R32 Refrigerant is more environmentally friendly than R410a widely used in the last years. R32 has also zero impact on the ozone layer and it has 75% less impact on global warming vs R410A.

The ducted systems are the ideal solution for flexible, concealed air conditioning and the optional 200mm spigots ensure simple, hassle-free connection to spiral ductwork.

Model Reference
Nom.
Cool
(kW)

Nom.
Heat
(kW)

Max
Pipe
(m)
EuP Lot 10
Energy Rating

Fuse
(Amps)
In/Out

Pipe
Size
Gas

Pipe
Size
Liquid

Electrical
Supply
Indoor Unit ModelOutdoor Unit ModelSCOPSEER
S-60PF1E5BU-60PZ2E56.006.00404.206.10205/83/8Single
S-71PF1E5BU-71PZ2E57.107.10404.306.10205/83/8Single
S-100PF1E5BU-100PZ2E510.0010.00503.805.60255/83/8Single
S-125PF1E5BU-125PZ2E512.5012.50503.615.56305/83/8Single
S-140PF1E5BU-140PZ2E514.0014.00503.545.38305/83/8Single
S-100PF1E5BU-100PZ2E810.0010.00503.805.60165/83/8Three
S-125PF1E5BU-125PZ2E812.5012.50503.615.56165/83/8Three
S-140PF1E5BU-140PZ2E814.0014.00503.545.38165/83/8Three

System Combination

  • Indoor Unit(s)
  • Condensing Unit
  • CZ-RTC4 Controller (quoted by Logicool as standard option)

Options

Features and Benefits

  • DC FAN for better efficiency and control
  • Easy connection and control of external fan or ERV using the connector PAW-FDC on the indoor unit PCB. The external device can be control by the remote control of the Panasonic indoor unit
  • PAC-i R32 Standard Seasonal Inverter
  • High ESP (external static pressure) up to 150 Pa
  • High ESP (external static pressure) up to 150 Pa
  • Cooling to -15°C
  • Heating to -20°C
  • R22 Replacement Technology
  • Twin split configurations available
  • Automatic learning function for the required static pressure on site during commissioning*
  • CZ-RTC5B EcoNavi Ready controller available as an option.
  • Built in drain pump

POWER/WIRING: Panasonic PAC-i systems require a separate power supply to Indoor (3 Amp isolator for all units) and Outdoor Units. It is also possible to supply power to outdoor unit only, and run power to indoor via a 3 core flex from a field supplied fused terminal block. A separate 2 core 0.75mm² screened cable will also be required for data connection

 

Advanced Technical Data

Indoor Unit Technical Data
ModelS-36PF1E5BS-50PF1E5BS-60PF1E5BS-71PF1E5BS-100PF1E5BS-125PF1E5BS-140PF1E5B
Cooling (kW) - Nominal3.605.006.007.1010.0012.5014.00
Heating (kW) - Nominal3.605.006.007.1010.0012.5014.00
Cooling (kW) - UK 23°C DB / 30°C)Multi Only (Splits late 2018)10.7012.6013.90
Heating (kW) - UK (20° / -8°)Multi Only(Splits late 2018)11.8014.5014.70
Sensible Heat Capacity (KW) - NominalTBCTBCTBCTBC9.4010.4011.00
Sound Pressure Level (dBA)33/29/2534/30/2635/32/2635/32/2638/34/3139/35/3240/36/33
Height - mm 290
Width - mm 70070010001000140014001400
Depth - mm 700
Weight - kG 28283333454545
Air Flow Rate (m³/min)14/13/1016/15/1221/19/1521/19/1532/26/2134/29/2336/32/25
Fused Spur (A)5
Outdoor Unit Technical Data
CombinationsSingleSingle and Twin
ModelU-60PZ2E5U-71PZ2E5U-100PZ2E5(8)U-125PZ2E5(8)U-140PZ2E5(8)
Height (mm)6956959969961416
Width (mm)875875980940940
Depth (mm)320320370340340
Weight (kG)4444909494
Airflow (m3/min)40 / 4550 / 4576 / 7086 / 7889 / 83
Sound Pressure Cooling (dBA)4849525556
Sound Power Cooling (dBA)6869707374
Liquid (mm(inches))9.52 (3/8)
Gas (mm(inches))15.88 (5/8)
Max Pipe Run (m)4050
Max Pipe Lift (m)30 (15 if condenser is lower than IU)
Pre-charged to (m)30
Standing Charge (kG)1.451.452.62.982.98
Additional Charge/m (g)3535454545
RefrigerantR32
PhaseSingleSingle (Three)
Power Supply toIU (5A) and OU or OU with feed to IU
Max Current (A)16.416.3425.029.030.0
Fuse Rating (A)202025 (16)32 (16)32 (16)
Interconnecting2C Screen 0.75mm²
Twin Pipe KitCZ-P224BK2BM