Elite Big PAC-i PE4 Indoor (R32)

Enquire Now

New PE4 Series Panasonic Big PAC-i NX High Static Pressure Ducted 20.0-25.0kW

1. The compact outdoor unit with one fan will fit in limited installation space · Compact outdoor unit with single fan, height only 996mm · Highly efficient with compact body

2. Easy and flexible pipework and installation · High external static pressure, maximum 200Pa1) setting · Split-able hide-away indoor design for easy & flexible piping work · Long piping allowance maximum 100m · Extended operation range up to 52°C in cooling, down to -20°C in heating

3. Comfort operation with nanoe™ X · Better indoor air quality with nanoe™ X (Generator Mark 3: 48 trillion hydroxyl radicals/sec) as standard for better indoor air quality · Smartphone control-ready with Panasonic Comfort Cloud App2)

Model Reference
Nom.
Cool
(kW)

Nom.
Heat
(kW)

Max
Pipe
(m)
EuP Lot 10
Energy Rating

Fuse
(Amps)

Pipe
Size
Gas

Pipe
Size
Liquid

Electrical
Supply
IU/OU
Indoor UnitOutdoor UnitSCOP/ηsc (2)SEER/ηsc (2)
S-200PE4EU-200PZH4E819.022.40100237.8%213.0%327/81/2Single/Three
S-250PE4EU-250PZH4E822.024.00100146.0%145.0%327/81/2Single/Three

Features and Benefits

  • New Compact Condensing Unit Height – less than 1000mm
  • Ease of installation – Indoor Unit can be split into three lightweight components (48, 28 & 11kG)
  • Higher efficiency with SEER of 6.02 and SCOP of 3.73
  • New Single Phase Indoor Unit
  • Connects to PZH4 Condensing Units
  • High External Static Pressure of up to 200Pa
  • New improved wiring – 4 Core with mains power to Outdoor Unit
  • Indoor unit can be disassembled down to Heat Exchanger and Fan Assemblies to allow for installation in tight spaces. Ideal for Retrofit solutions.
  • Indoor Unit contains Nanoe-X Technology with the capacity to inhibit 5 types of pollutants: Bacteria and viruses- Mould – Allergens – Pollen – Hazardous substances
  • Increased pipe-run of up to 100m
  • 0-10V control demand

Power/Wiring

Panasonic PAC-i Generation 3 and 4 systems require a power supply to the Outdoor Condensing Unit. Indoor Unit supply is fed via a 4 core flex from the Condensing Unit. A separate 2 core 0.75mm² screened cable will also be required for data connection

Ease of Installation by splitting into three separate components to allow access into existing ceilings

 

 

Advanced Technical Data

Indoor Units

Indoor Unit Technical Data
ModelS-200PE4ES-250PE4E
Cooling (kW) - Nominal19.0022.00
Heating (kW) - Nominal22.4024.00
Cooling (kW) - Max SEER Condition20.0025.60
Heating (kW) - Max SCOP Avg Climate Condition24.5027.60
Sensible Heat Ratio (SHR)87.90%82.70%
Noise Level H/M/L (dBA)46/44/4147/45/42
Static Pressure (Pa)75/120/18075/130/200
Height - mm486486
Width - mm14561456
Depth - mm916916
Weight - kG (grille)8387
Air Flow Rate (l/sec)883/1050/1198983/1200/1400
Fused Spur (A)55

 

Back to products
Add selected to wishlist