air365 MAX 2/3 Pipe with AirTap

Enquire Now

HITACHI AIR 365 VRF

air365, the new cutting-edge VRF

Hitachi, with its expertise in VRF, has developed a new range to go even further, by offering exclusive technologies with the new air365 VRF

Unique groups for 2-pipe/3-pipe application capacity from 14kW to 268kW

Features Air Cloud TAP NFX Technology

Feature and Benefits

  • New Hitachi Scroll Compressor with hot gas injection
  • The airCloud Tap mobile application allows the configuration of outdoor groups and indoor units by NFC contact.
    • Indoor Unit parameters
    • External Group Settings
    • Function Test
    • Reading of operation parameters

  • SINGLE BODY 24HP MODEL
  • Wide choice of compatible remote controllers
  • Smooth Drive 2.0 Technology
  • Patented Oil Return Circuit
  • Smart Defrost to maintain comfort
  • 80Pa ESP
  • Anti-corrosion exchanger with 3 layers of protection
  • Compatible with existing Hitachi Set-Free Indoor Units, CH Boxes and Controllers. 
  • Wide product range with single modules available from 8 to 24HP (standard) and 5 to 18HP (high efficiency)
  • Combine 4 base outdoor units to achieve up to 96HP with a single system
  • Smooth Drive Control adjusts outdoor unit capacity in 0.1Hz increments, expanding the working range down to 5% of maximum capacity for enhanced seasonal efficiency at part loads
  • User comfort ensured with variable refrigerant temperature and controllable off coil temperatures to eliminate cold draught
  • Extended height difference of up to 110m between indoor and outdoor units
  • Improved static pressure (80Pa) for outdoor unit installation flexibility
  • ‘Smart Building’ ready for future proof installations
  • Low noise operation, down -14 db(A)
  • Efficient defrost cycles ensure continuous heating to enhance user comfort
  • Installation flexibility with indoor units up 150% capacity of outdoor
  • Market leading low refrigerant charge
  • Motion sensor for up to 14% energy savings with System Free cassettes, ceiling suspended and ducted indoor units.
  • Cooling to -10 Degrees Celsius
  • Heating to -15 Degrees Celsius

 

Model Reference
Nom
Cool
(Kw)

Nom
Heat
(Kw)

Efficiency
Heat/Cool

Fuse
Rating
Amps

Pipe
Size
Gas/Liquid

Pipe
Size
HP Gas*

Body
Size
(No. of Modules)

System
Combination
Combination/DiversityOutdoor Unit ModelSCOPSEER
Max 26 FC, 150%RAS-8FSXNS2E22.4022.404.637.35203/4 + 3/85/8Single8
Max 32 FC, 150%RAS-10FSXNS2E28.0028.004.567.12257/8 + 3/83/4Single10
Max 39 FC, 150%RAS-12FSXNS2E33.5033.504.296.79321 1/8 + 1/2**7/8Single12
Max 45 FC, 150%RAS-14FSXNS2E40.0040.004.516.91321 1/8 + 1/2**7/8Single14
Max 52 FC, 150%RAS-16FSXNS2E45.0045.004.677.20401 1/8 + 1/27/8Single16
Max 58 FC, 150%RAS-18FSXNS2E50.0050.004.356.73501 1/8 + 5/87/8Single18
Max 64 FC, 150%RAS-20FSXNS2E56.0056.004.766.43501 1/8 + 5/87/8Single20
Max 64 FC, 150%RAS-22FSXNS2E61.5061.504.346.17501 1/8 + 5/81 1/8**Single22
Max 64 FC, 150%RAS-24FSXNS2E67.0067.004.276.19631 1/8 + 5/81 1/8**Single24
Max 64 FC, 150%RAS-26FSXNS2E73.5073.504.326.75








Please
check
module
combination
1 3/8 + 3/41 1/8**Twin14 + 12
Max 64 FC, 150%RAS-28FSXNS2E78.5078.504.386.901 3/8 + 3/41 1/8Twin16 + 12
Max 64 FC, 150%RAS-30FSXNS2E83.5083.504.206.671 3/8 + 3/41 1/8Twin18 + 12
Max 64 FC, 150%RAS-32FSXNS2E90.0090.004.356.801 3/8 + 3/41 1/8Twin18 + 14
Max 64 FC, 150%RAS-34FSXNS2E95.0095.004.406.931 3/8 + 3/41 1/8Twin18 + 16
Max 64 FC, 150%RAS-36FSXNS2E100.00100.004.256.731 5/8 + 3/41 1/8Twin18 + 18
Max 64 FC, 150%RAS-38FSXNS2E106.50106.504.406.551 5/8 + 3/41 3/8Twin22 + 16
Max 64 FC, 150%RAS-40FSXNS2E111.50111.504.276.401 5/8 + 3/41 3/8Twin22 + 18
Max 64 FC, 150%RAS-42FSXNS2E117.00117.004.246.401 5/8 + 3/41 3/8Twin24 + 18
Max 64 FC, 150%RAS-44FSXNS2E123.00123.004.296.171 5/8 + 3/41 3/8Twin22 + 22
Max 64 FC, 150%RAS-46FSXNS2E128.50128.504.266.181 5/8 + 3/41 3/8Twin24 + 22
Max 64 FC, 150%RAS-48FSXNS2E134.00134.004.246.191 5/8 + 3/41 3/8Twin24 + 24
Max 64 FC, 150%RAS-50FSXNS2E140.00140.004.326.781 5/8 + 3/41 3/8Triple18 + 18 + 14
Max 64 FC, 150%RAS-52FSXNS2E145.00145.004.356.861 5/8 + 3/41 3/8Triple18 + 18 + 16
Max 64 FC, 150%RAS-54FSXNS2E150.00150.004.256.731 5/8 + 3/41 3/8Triple18 + 18 + 18
Max 64 FC, 150%RAS-56FSXNS2E156.50156.504.356.612 1/8 + 3/4N/ATriple22 + 18 + 16
Max 64 FC, 150%RAS-58FSXNS2E161.50161.504.266.502 1/8 + 3/4N/ATriple22 + 18 + 18
Max 64 FC, 150%RAS-60FSXNS2E167.00167.004.246.502 1/8 + 3/4N/ATriple24 + 18 + 18
Max 64 FC, 150%RAS-62FSXNS2E173.00173.004.286.312 1/8 + 3/4N/ATriple22 + 22 + 18
Max 64 FC, 150%RAS-64FSXNS2E178.50178.504.256.212 1/8 + 3/4N/ATriple24 + 22 + 18
Max 64 FC, 150%RAS-66FSXNS2E184.00184.004.236.322 1/8 + 3/4N/ATriple24 + 24 + 18
Max 64 FC, 150%RAS-68FSXNS2E190.00190.004.276.172 1/8 + 7/8N/ATriple24 + 22 + 22
Max 64 FC, 150%RAS-70FSXNS2E195.50195.504.256.182 1/8 + 7/8N/ATriple24 + 24 + 22
Max 64 FC, 150%RAS-72FSXNS2E201.00201.004.246.192 1/8 + 7/8N/AQuad24 + 24 + 24
Max 64 FC, 150%RAS-74FSXNS2E206.50206.504.336.632 1/8 + 7/8N/AQuad22 + 18 + 18 + 16
Max 64 FC, 150%RAS-76FSXNS2E211.50211.504.266.552 1/8 + 7/8N/AQuad22 + 18 + 18 + 18
Max 64 FC, 150%RAS-78FSXNS2E217.00217.004.246.552 1/8 + 7/8N/AQuad24 + 18 + 18 + 18
Max 64 FC, 150%RAS-80FSXNS2E223.00223.004.276.402 1/8 + 7/8N/AQuad22 + 22 + 18 + 18
Max 64 FC, 150%RAS-82FSXNS2E228.50228.504.256.402 1/8 + 7/8N/AQuad24 + 22 + 18 + 18
Max 64 FC, 150%RAS-84FSXNS2E234.00234.004.246.402 1/8 + 7/8N/AQuad24 + 24 + 18 + 18
Max 64 FC, 150%RAS-86FSXNS2E240.00240.004.266.282 1/8 + 7/8N/AQuad24 + 22 + 22 + 18
Max 64 FC, 150%RAS-88FSXNS2E245.50245.504.256.282 1/8 + 7/8N/AQuad24 + 24 + 22 + 18
Max 64 FC, 150%RAS-90FSXNS2E251.00251.004.236.292 1/8 + 1 1/8N/AQuad24 + 24 + 24 + 18
Max 64 FC, 150%RAS-92FSXNS2E257.00257.004.266.182 1/8 + 1 1/8N/AQuad24 + 24 + 22 + 22
Max 64 FC, 150%RAS-94FSXNS2E262.50262.504.256.182 1/8 + 1 1/8N/AQuad24 + 24 + 24 + 22
Max 64 FC, 150%RAS-96FSXNS2E268.00268.004.246.192 1/8 + 1 1/8N/AQuad24 + 24 + 24 + 24

* These models are for 2-Pipe Heat Pump and 3-Pipe Heat Recovery Installation. Use High Pressure (HP) gas size only for 3-Pipe Heat Recovery Installation

** Indicates 1″ Connection. Please contact Logicool for final pipe sizing and schematics

Note that the above table details FSXNS2E Standard-Efficiency model. Please click here for FSXNP2E High-Efficiency Models