Feature and Benefits
Model Reference | Nom Cool (Kw) | Nom Heat (Kw) | Efficiency Heat/Cool | Fuse Rating Amps | Pipe Size Gas/Liquid | Pipe Size HP Gas* | Body Size (No. of Modules) | System Combination |
||
Combination/Diversity | Outdoor Unit Model | SCOP | SEER | |||||||
Max 16 FC, 150% | RAS-5FSXNSPE | 14.00 | 14.00 | 5.29 | 7.75 | 16 | 3/4 + 3/8 | 5/8 | Single | 5 |
Max 19 FC, 150% | RAS-6FSXNSPE | 16.00 | 16.00 | 4.69 | 7.62 | 16 | 3/4 + 3/8 | 5/8 | Single | 6 |
Max 26 FC, 150% | RAS-8FSXNP2E | 22.40 | 22.40 | 4.94 | 8.38 | 20 | 7/8 + 3/8 | 3/4 | Single | 8 |
Max 32 FC, 150% | RAS-10FSXNP2E | 28.00 | 28.00 | 4.66 | 7.80 | 32 | 7/8 + 3/8 | 3/4 | Single | 10 |
Max 39 FC, 150% | RAS-12FSXNP2E | 33.50 | 33.50 | 4.46 | 7.41 | 32 | 1 1/8 + 1/2** | 7/8 | Single | 12 |
Max 45 FC, 150% | RAS-14FSXNP2E | 40.00 | 40.00 | 4.15 | 7.25 | 40 | 1 1/8 + 1/2** | 7/8 | Single | 14 |
Max 52 FC, 150% | RAS-16FSXNP2E | 45.00 | 45.00 | 4.17 | 7.45 | 40 | 1 1/8 + 1/2 | 7/8 | Single | 16 |
Max 58 FC, 150% | RAS-18FSXNP2E | 50.00 | 50.00 | 3.76 | 7.09 | 50 | 1 1/8 + 5/8 | 7/8 | Single | 18 |
Max 64 FC, 150% | RAS-20FSXNP2E | 56.00 | 56.00 | 4.66 | 7.44 | Please check module combination | 1 1/8 + 5/8 | 7/8 | Single | 10 + 10 |
Max 64 FC, 150% | RAS-22FSXNP2E | 61.50 | 61.50 | 4.55 | 7.30 | 1 1/8 + 5/8 | 1 1/8** | Single | 12 + 10 | |
Max 64 FC, 150% | RAS-24FSXNSPE | 67.00 | 67.00 | 4.46 | 7.19 | 1 1/8 + 5/8 | 1 1/8** | Single | 12 + 12 | |
Max 64 FC, 150% | RAS-26FSXNP2E | 73.00 | 73.00 | 4.33 | 7.45 | 1 3/8 + 3/4 | 1 1/8** | Twin | 16 + 10 | |
Max 64 FC, 150% | RAS-28FSXNP2E | 78.50 | 78.50 | 4.28 | 7.33 | 1 3/8 + 3/4 | 1 1/8 | Twin | 16 + 12 | |
Max 64 FC, 150% | RAS-30FSXNP2E | 83.50 | 83.50 | 4.02 | 7.11 | 1 3/8 + 3/4 | 1 1/8 | Twin | 18 + 12 | |
Max 64 FC, 150% | RAS-32FSXNP2E | 90.00 | 90.00 | 3.73 | 7.15 | 1 3/8 + 3/4 | 1 1/8 | Twin | 18 + 14 | |
Max 64 FC, 150% | RAS-34FSXNP2E | 95.00 | 95.00 | 3.94 | 7.25 | 1 3/8 + 3/4 | 1 1/8 | Twin | 18 + 16 | |
Max 64 FC, 150% | RAS-36FSXNP2E | 100.00 | 100.00 | 3.76 | 7.09 | 1 5/8 + 3/4 | 1 1/8 | Twin | 18 + 18 | |
Max 64 FC, 150% | RAS-38FSXNP2E | 107.00 | 107.00 | 4.13 | 7.19 | 1 5/8 + 3/4 | 1 3/8 | Triple | 14 + 12 + 12 | |
Max 64 FC, 150% | RAS-40FSXNP2E | 113.50 | 113.50 | 3.88 | 7.21 | 1 5/8 + 3/4 | 1 3/8 | Triple | 14 + 14 + 12 | |
Max 64 FC, 150% | RAS-42FSXNP2E | 120.00 | 120.00 | 3.68 | 7.24 | 1 5/8 + 3/4 | 1 3/8 | Triple | 14 + 14 + 14 | |
Max 64 FC, 150% | RAS-44FSXNSPE | 123.50 | 123.50 | 3.90 | 7.15 | 1 5/8 + 3/4 | 1 3/8 | Triple | 18 + 14 + 12 | |
Max 64 FC, 150% | RAS-46FSXNP2E | 130.00 | 130.00 | 3.71 | 7.18 | 1 5/8 + 3/4 | 1 3/8 | Triple | 18 + 14 + 14 | |
Max 64 FC, 150% | RAS-48FSXNP2E | 135.00 | 135.00 | 3.86 | 7.25 | 1 5/8 + 3/4 | 1 3/8 | Triple | 18 + 16 + 14 | |
Max 64 FC, 150% | RAS-50FSXNP2E | 140.00 | 140.00 | 3.74 | 7.13 | 1 5/8 + 3/4 | 1 3/8 | Triple | 18 + 18 + 14 | |
Max 64 FC, 150% | RAS-52FSXNP2E | 145.00 | 145.00 | 3.87 | 7.20 | 1 5/8 + 3/4 | 1 3/8 | Triple | 18 + 18 + 16 | |
Max 64 FC, 150% | RAS-54FSXNP2E | 150.00 | 150.00 | 3.76 | 7.09 | 1 5/8 + 3/4 | 1 3/8 | Triple | 18 + 18 + 18 |
* These models are for 2-Pipe Heat Pump and 3-Pipe Heat Recovery Installation. Use High Pressure (HP) gas size only for 3-Pipe Heat Recovery Installation
** Indicates 1″ Connection. Please contact Logicool for final pipe sizing and schematics
Note that the above table details FSXNP2E Higher-Efficiency model. Please click here for FSXNS2E Standard Efficiency Air 365 Models