Set-Free Sigma High Efficiency 2/3 Pipe

Enquire Now

HITACHI SIGMA MODULAR VRF

Single Unit solution (2-pipe/3-pipe) FSXNPE High Efficiency System

Sigma VRF has been specially designed for easier installation, commissioning and maintenance. Its flexible modular system achieves higher power combinations from fewer units, requiring less space, fewer pipe connections and delivering an installer friendly experience.

Improved energy efficiency is achieved with a new, revolutionary DC inverter scroll compressor, Sigma shaped heat exchanger and new fan design to improve air flow. All units are compatible with Hitachi’s System Free indoor units, including Hydro Free water modules, for the most flexible VRF system on the market.

Refrigerant R410a system with industry-leading lowest comparable total charge

Model Reference
Nom
Cool
(Kw)

Nom
Heat
(Kw)

Efficiency
Heat/Cool

Fuse
Rating
Amps

Pipe
Size
Gas/Liquid

Pipe
Size
HP Gas*

Body
Size
(No. of Modules)
Combination/DiversityOutdoor Unit ModelSCOPSEER
Max 16 FC, 150%RAS-5FSXNPE14.0016.005.068.33165/8 + 3/85/8Single
Max 19 FC, 150%RAS-6FSXNPE16.0018.004.588.00163/4 + 3/85/8Single
Max 26 FC, 150%RAS-8FSXNPE22.4025.004.557.97163/4 + 3/85/8Single
Max 32 FC, 150%RAS-10FSXNPE28.0031.504.738.06203/4 + 3/83/4Single
Max 39 FC, 150%RAS-12FSXNPE33.5037.504.817.91251 1/8 + 1/2**7/8Single
Max 45 FC, 150%RAS-14FSXNPE40.0045.004.637.69321 1/8 + 1/2**7/8Single
Max 52 FC, 150%RAS-16FSXNPE45.0050.004.847.76401 1/8 + 1/27/8Single
Max 58 FC, 150%RAS-18FSXNPE50.0056.004.817.60401 1/8 + 5/87/8Twin
Max 64 FC, 150%RAS-20FSXNPE56.0063.004.748.0620 / 201 1/8 + 5/87/8Twin
Max 64 FC, 150%RAS-22FSXNPE61.5069.004.717.9725 / 201 1/8 + 5/81 1/8**Twin
Max 64 FC, 150%RAS-24FSXNPE67.0077.503.687.9125 / 251 1/8 + 5/81 1/8**Twin
Max 64 FC, 150%RAS-26FSXNPE73.0082.504.177.9240 / 251 3/8 + 3/41 1/8**Twin
Max 64 FC, 150%RAS-28FSXNPE77.5090.004.187.7140 / 251 3/8 + 3/41 1/8Twin
Max 64 FC, 150%RAS-30FSXNPE85.0095.004.077.4340 / 251 3/8 + 3/41 1/8Twin
Max 64 FC, 150%RAS-32FSXNPE90.00100.003.807.6240 / 321 3/8 + 3/41 1/8Twin
Max 64 FC, 150%RAS-34FSXNPE95.00106.003.747.8340 / 401 3/8 + 3/41 1/8Twin
Max 64 FC, 150%RAS-36FSXNPE100.00112.004.647.6040 / 401 5/8 + 3/41 1/8Twin
Max 64 FC, 150%RAS-38FSXNPE106.00118.004.747.6732 / 25 / 251 5/8 + 3/41 3/8Triple
Max 64 FC, 150%RAS-40FSXNPE112.00125.004.687.6732 / 32 / 251 5/8 + 3/41 3/8Triple
Max 64 FC, 150%RAS-42FSXNPE118.00132.004.637.6732 / 32 / 321 5/8 + 3/41 3/8Triple
Max 64 FC, 150%RAS-44FSXNPE122.00140.004.687.6440 / 32 / 251 5/8 + 3/41 3/8Triple
Max 64 FC, 150%RAS-46FSXNPE128.00145.004.637.6440 / 32 / 321 5/8 + 3/41 3/8Triple
Max 64 FC, 150%RAS-48FSXNPE136.00150.004.687.6140 / 40 / 251 5/8 + 3/41 3/8Triple
Max 64 FC, 150%RAS-50FSXNPE140.00155.004.647.6140 / 40 / 321 5/8 + 3/41 3/8Triple
Max 64 FC, 150%RAS-52FSXNPE145.00160.004.707.7540 / 40 / 401 5/8 + 3/41 3/8Triple
Max 64 FC, 150%RAS-54FSXNPE150.00165.004.607.6040 / 40 / 401 5/8 + 3/41 3/8Triple

* These models are for 2-Pipe Heat Pump and 3-Pipe Heat Recovery Installation. Use High Pressure (HP) gas size only for 3-Pipe Heat Recovery Installation

** Indicates 1″ Connection. Please contact Logicool for final pipe sizing and schematics

Note that the above table details FSXNPE High-Efficiency model. Please click here for FSXNSE Standard-Efficiency Models

Feature and Benefits

  • Market leading SCOP up to 5.06 and SEER up to 8.33
  • Wide product range with single modules available from 8 to 24HP (standard) and 5 to 18HP (high efficiency)
  • Combine 4 base outdoor units to achieve up to 96HP with a single system
  • Smooth Drive Control adjusts outdoor unit capacity in 0.1Hz increments, expanding the working range down to 5% of maximum capacity for enhanced seasonal efficiency at part loads
  • User comfort ensured with variable refrigerant temperature and controllable off coil temperatures to eliminate cold draught
  • Extended height difference of up to 110m between indoor and outdoor units
  • Improved static pressure (80Pa) for outdoor unit installation flexibility
  • ‘Smart Building’ ready for future proof installations
  • Low noise operation, down -14 db(A)
  • Efficient defrost cycles ensure continuous heating to enhance user comfort
  • Installation flexibility with indoor units up 150% capacity of outdoor
  • Market leading low refrigerant charge
  • Motion sensor for up to 14% energy savings with System Free cassettes, ceiling suspended and ducted indoor units.
  • Cooling to -10 Degrees Celsius
  • Heating to -15 Degrees Celsius

Compatible System and Set-Free Products

Product Images

Back to products