Utopia Prime Standard Heat Pump

Enquire Now

Hitachi’s Utopia Prime Standard Heat Pump range are high specification single and multi-split systems with an increased number of twin, triple and quad combinations in addition to delivering excellent part-load efficiency.

Designed for use as Single, Twin, Triple or Quad Split Systems

With cooling capacities and heating capacities from 10.0kW to 14.0kW, a maximum of 4 indoor units are connectable to a single outdoor unit,

Twin and, Triple and Quad Combinations Possible (All on or all off – not VRF Control)

Model Reference
Nom
Cool/Heat
(kw)

Refrigerant
Type

Max
Pipe
(m)

Fuse
Rating
(Amps)

Pipe
Size
Gas

Pipe
Size
Liquid

Inter-
Connecting
Cable

Electrical
Supply
Max. IndoorsOutdoor Unit
Max 1 FC, 100%RAS-2HVRC25.00 / 5.00R3250161/21/43C + 2C*Single
Max 1 FC, 100%RAS-2.5HVRC25.60 / 5.60R3250161/21/43C + 2C*Single
Max 2 FC, 90 - 100%RAS-3HVRC27.10 / 7.10R3250205/83/83C + 2C*Single
Max 4 FC, 90 - 115%RAS-4HVRC2E10.00 / 10.00R3275255/83/83C + 2C*Single
Max 4 FC, 90 - 115%RAS-5HVRC2E11.90 / 11.90R3275255/83/83C + 2C*Single
Max 4 FC, 90 - 115%RAS-6HVRC2E14.00 / 14.00R3275255/83/83C + 2C*Single
Max 4 FC, 90 - 115%RAS-4HRC2E10.00 / 10.00R3275205/83/83C + 2C*Three
Max 4 FC, 90 - 115%RAS-5HRC2E11.90 / 11.90R3275205/83/83C + 2C*Three
Max 4 FC, 90 - 115%RAS-6HRC2E14.00 / 14.00R3275205/83/83C + 2C*Three

 

Compatible Indoor Units

Features and Benefits

  • Ability to utilise any Hitachi System-Free Indoor Unit
  • Flexible connections – can connect indoor units with capacities as low as 2kW in Multi Configuration
  • SCOP as high as 4.73 and SEER as high as 7.35 (twin Cassette 14kW example)
  • Cooling capacities from 7.1W to 14.0kW (True 12Hp/30kW Condensing Unit)
  • Heating capacities from 8.0kW to 16.0kW
  • Compact design – single fan (up to 6HP)
  • R32 refrigerant for models up to 14kW
  • Improved connectivity – up to 4 indoors per outdoor unit minimising pipework required
  • Fully ErP compliant with A++ seasonal efficiency
  • Decreased Defrost Operation and Extended Heating Operation
  • Available in single phase and three phase.

 

Comfort and ease of installation

Improved connectivity (up to 4 indoors per outdoor unit, minimising pipework required)

The individual Thermo-on and Thermo-off is possible even when the remote control is connected to multiple internal units.

The system is able to handle changes in air conditioning needs for each individual space, e.g., internal zone or perimeter area, and thereby optimise energy efficiencies.

This produces a highly comfortable environment and great electricity savings.

Easily adaptable and reconfigurable

Each indoor unit can be operated completely independently within the same mode.

Controlled from a dedicated remote controller, each room’s occupants can monitor and adjust operating temperatures according to their specific requirements.

This facilitates maximum energy savings and total future flexibility, as units have individual control regardless
of possible future reorganisation of the interior spaces.

Compatibility with R22 pipework

New Utopia IVX Comfort (and IVX Premium) are compatible* with existing R22 gas installations. Both models – which use R410A refrigerant gas – can be installed without having to change the existing installed piping as the system adjusts the pressure so as
not to damage the existing piping.

 

Advanced Technical Data

Outdoor Unit Technical DataModel ReferenceModel ReferenceModel Reference
Connectivity111 - 21 - 41 - 41 - 4
VRF OperationNo - Single Controller per System Only
ModelRAS-2HVRC3RAS-2.5HVRC3RAS-3HVRC3RAS-4H(V)RC2ERAS-5H(V)RC2ERAS-6H(V)RC2E
Height (mm)6291140
Width (mm)799 (+99)950
Depth (mm)300 (+65)370
Weight (kG)40404384
Airflow Cooling (m3/min)45.945.949.7808080
Airflow Heating (m3/min)45.945.957.0808080
Sound Pressure Cooling (dBA)454552545456
Sound Pressure Sound Pressure Cooling Night Mode (dBA)424348515151
Sound Power Cooling (dBA)656568707072
Liquid (mm(inches))6.38 (1/4)6.38 (1/4)9.52 (3/8)9.52 (3/8)9.52 (3/8)9.52 (3/8)
Gas (mm(inches))12.70 (1/2)12.70 (1/2)15.88 (5/8)15.88 (5/8)15.88 (5/8)15.88 (5/8)
Max Pipe Run (m)505050757575
Min Pipe Run (m)555
Max Pipe Lift (m)30 / 20 (higher OU / lower OU)30 / 20 (higher OU / lower OU)30 / 20 (higher OU / lower OU)
Pre-charged to (m)303030202020
Standing Charge (kG)1.31.31.83.03.03.0
Additional charge (g/m)242430454545
RefrigerantR32
PhaseSingleSingleSingleSingle (Three)Single (Three)Single (Three)
Power Supply toIndoor / Outdoor (see notes below)
Run Current Cool/Heat(A)5.5 / 5.46.0 / 6.28.2 / 7.512.4 / 12.8 (4.4 / 4.5)16.3 / 17.0 (5.7 / 6.0)21.1 / 17.6 (7.4 / 6.2)
Max Current (A)12.512.516.522.5 (15)22.5 (15)22.5 (15)
Fuse Rating (A)16162025 (20)25 (20)25 (20)
Interconnecting2C 0.75mm Screened Cable (note that power can also be fed from condenser separately via inline fuse)
System Power Input (Cool/Heat) - kWTBCTBCTBC2.56 / 2.653.38 / 3.524.38 / 3.64
Pipe Kit Required (Twin)N/AN/AE-102SN4
Pipe Kit Required (Triple)N/AN/AN/AE-102SN4 x 2
Pipe Kit Required (Quad)N/AN/AN/AE-102SN4 x 3
Back to products