Model Reference | Nom. Cool/Sens (kW) | Nom. Heat (kW) | Max Pipe | EuP Lot 10 Energy Rating | Fuse (Amps) | Pipe Gas | Pipe Liquid | R22 Replace | Electrical Supply |
||
Indoor Unit | Outdoor Unit | SCOP | SEER | ||||||||
RAK-18PEC | RAC-18WEC | 2.00 / 1.99 | 2.50 | 20 | 3.80 | 5.80 | 16 | 3/8 | 1/4 | No | Single |
RAK-25PEC | RAC-25WEC | 2.50 / 2.28 | 3.40 | 20 | 3.80 | 5.80 | 16 | 3/8 | 1/4 | No | Single |
RAK-35PEC | RAC-35WEC | 3.50 / 2.87 | 4.20 | 20 | 3.80 | 5.80 | 16 | 3/8 | 1/4 | No | Single |
RAK-50PEC | RAC-50WEC | 5.00 / 3.47 | 6.00 | 20 | 3.80 | 5.88 | 25 | 1/2 | 1/4 | No | Single |
Features and Benefits
Power/Wiring:
Power supply to Outdoor Unit with 3C + E interconnecting cable. Note that this is 240vAC plus Comms.
Product Images
Advanced Technical Data
Indoor Unit Technical Data | Model Reference | |||
RAK-18PEC | RAK-25PEC | RAK-35PEC | RAK-50PEC | |
Cooling (kW) - Nominal | 2 | 2.5 | 3.5 | 5 |
Heating (kW) - Nominal | 2.5 | 3.4 | 4.2 | 6 |
Cooling (kW) - UK Condition | Pending | Pending | Pending | Pending |
Heating (kW) - UK Condition | Pending | Pending | Pending | Pending |
Sensible Heat Ratio (SHR) | 95.00% | 88.00% | 80.00% | 68.00% |
Sound Pressure - Cooling (dBA) | 37-24/21 | 40-24/22 | 43-26/25 | 46-30/28 |
Sound Pressure - Heating (dBA) | 38-22/19 | 41-23/20 | 44-27/26 | 47-30/25 |
Height (mm) | 280 | 280 | 280 | 300 |
Width (mm) | 780 | 780 | 780 | 780 |
Depth (mm) | 218 | 218 | 218 | 218 |
Weight (kG) | 7.5 | 7.5 | 7.5 | 8 |
Air Flow - Cooling (m³/hr) | 440-350/312 | 510-370/333 | 600-400/333 | 700-450/333 |
Air Flow - Heating (m³/hr) | 480-350/312 | 570-400/333 | 660-520/333 | 770-510/433 |
Outdoor Unit Technical Data | Model Reference | |||
RAC-18WEC | RAC-25WEC | RAC-35WEC | RAC-50WEC | |
Height (mm) | 530 | 530 | 530 | 600 |
Width (mm) | 660 | 660 | 660 | 792 |
Depth (mm) | 278 | 278 | 278 | 299 |
Weight (kG) | 27.5 | 27.5 | 27.5 | 40 |
Sound Pressure - Cooling (dBA) | 46 | 48 | 49 | 51 |
Sound Pressure - Heating (dBA) | 47 | 49 | 50 | 51 |
Liquid (mm(inches)) | 6.35 (1/4) | 6.35 (1/4) | 6.35 (1/4) | 6.35 (1/4) |
Gas (mm(inches)) | 9.52 (3/8) | 9.52 (3/8) | 9.52 (3/8) | 12.7 (1/2) |
Max Pipe Run | 20 | 20 | 20 | 20 |
Max Pipe Lift | 10 | 10 | 10 | 10 |
Pre-charged to (m) | 20 | 20 | 20 | 20 |
Standing Charge (kG) | 0.95 | 0.95 | 0.95 | 1.25 |
Refrigerant | R410a | R410a | R410a | R410a |
Additional Charge per metre (g) | N/A | N/A | N/A | N/A |
Phase | Single | Single | Single | Single |
Power Supply to | Outdoor | Outdoor | Outdoor | Outdoor |
Max Max Start/Run Current (A) | 3.52 / 4.39 | 4.65 / 5.61 | 5.63 / 7.39 | 7.56 / 11.96 |
Fuse Rating (A) | 16 | 16 | 16 | 25 |
Interconnecting | 3C + E* | 3C + E* | 3C + E* | 3C + E* |
System Power Input (Cool/Heat) - kW | 0.58/0.62 | 0.70/0.88 | 1.09/1.10 | 1.56/1.66 |