MXZ Multi-Split (R32)

Enquire Now

MXZ-F R32Inverter Heat Pump (3.3-12.2kW)

The R32 Multi-Split system allows up to four M Series or Mr Slim wall mounted, cassette, ducted or ceiling suspended indoor units of different capacities to be
operated from a single outdoor unit.

This makes it an economic and efficient answer for multi-room applications, whilst also offering space saving benefits.


Model Reference

Refrigerant

Nom.
Cool
(kW)

Nom.
Heat
(kW)
Total
Max
Pipe
(m)
Pipe
Max
Per
Indoor (m)

I/C
Cable
(Core)
Outdoor
Fuse
(Amps)

Pipe
Size

Electrical
Supply
Max. IndoorsOutdoor Unit
2MXZ-2F33VF






R32
3.304.002015






3 Core + Earth
(per indoor unit)
16





As per Indoor.
Check configuration
with install manual







Single Phase
2MXZ-2F42VF4.204.50302016
2MXZ-2F53VF5306.40302516
3MXZ-3F54VF5.407.00502525
3MXZ-3F68VF6.808.60602525
4MXZ-4F72VF7.208.60602525
4MXZ-4F83VF8.309.30702525
5MXZ-5F102VF10.2010.50802525
6MXZ-6F122VF12.2014.00802532

PLEASE CHECK COMPATIBILITY WITH LOGICOOL BEFORE QUOTING OR ORDERING EQUIPMENT

Features and Benefits

  • Up to six indoor units may be connected to a single outdoor unit
  • Energy saving inverter controlled outdoor unit adjusts compressor performance to economically match the demand for heating and cooling
  • Units may be added within the capacity of the system as requirements change
  • Capacities of indoor units may be mixed to suit individual rooms

Advanced Technical Data

PLEASE CHECK COMPATIBILITY WITH LOGICOOL BEFORE QUOTING OR ORDERING EQUIPMENT

R32 (3.30 to 7.20kW Models)

Outdoor Unit Technical DataModel Reference
MXZ-2F33VFMXZ-2F42VFMXZ-3F54VFMXZ-3F68VFMXZ-4F72VF
Number Of Connectable Indoor Units222-32-32-4
Heat (Nominal)4.0 (1.0-4.1)4.5 (1.0-4.8)7.0 (2.6-9.0)8.6 (2.6-10.6)8.6 (3.4-10.7)
Cool (Nominal)3.3 (1.1-3.8)4.2 (1.1-4.4)5.4 (2.9-6.8)6.8 (2.9-8.4)7.2 (3.7-8.8)
Heat (UK)3.32 (0.83-3.40)3.74 (0.84-3.99)5.81 (2.16-7.47)7.14 (2.16-8.80)7.14 (2.82-8.89)
Cool (UK)3.23 (1.07-3.72)4.12 (1.08-4.32)5.3 (2.85-6.67)6.66 (2.84-8.23)7.0 (3.59-8.56)
COP / EER (Nominal)4.40 / 3.905.10 / 4.304.60 / 4.104.50 / 3.704.60 / 3.90
Scop / Seer (Bsen14825)4.16 / 6.134.60 / 8.694.61 / 8.524.12 / 7.964.07 / 8.13
Erp Energy Efficiency CLASS Heat/CoolA+ / A++A++ / A+++A++ / A+++A+ / A++A+ / A++
Max Airflow (M3/Min) Heat/Cool33.7 / 32.933.3 / 27.743.0 / 42.143.0 / 42.143.0 / 42.1
Sound Pressure Level (Dba) Heat/Cool50 / 4950 / 4450 / 4653 / 4854 / 48
Sound Power Level (Dba) Cool6059596363
Dimensions (Mm) Width X Depth X Height800 x 285 x 550840 x 330 x 710
Weight (Kg)3337585859
Electrical Supply220-240v, 50Hz
PhaseSingle
Power Input (Kw) Heat/Cool (Nominal)0.909 / 0.8460.88 / 0.981.52 / 1.321.91 / 1.841.87 / 1.85
Power Input (Kw) Heat/Cool (UK)0.82 / 0.680.90 / 0.781.38 / 1.061.73 / 1.471.69 / 1.48
Starting Current (A)4.64.2710.510
Running Current (A) Heat/Cool [Max]4.6 / 4.3 [10.0]4.2 / 4.5 [12.2]7.0 / 5.9 [18.0]10.5 / 9.6 [18.0]10.0 / 9.5 [18.0]
Interconnecting Cable No. Cores4 Core
Total Pipe Length (M)20305060
Max Pipe Length Per Indoor Unit (M)152025
Pre-Charged To (M)20205060
Max Height Difference (M)1015 (10 if OU higher than IU)
Charge Refrigerant (Kg)11.21.4
Co2 Equivalent (T) - R32 (Gwp 675)0.680.810.950.950.95
Max Additional Refrigerant (Kg)11.42.4
Co2 Equivalent (T) - R32 (Gwp 675)0.680.951.62
Fuse Rating (Bs88) - HRC (A)161625

R32 (8.30 to 12.20kW Models)

Outdoor Unit Technical DataModel Reference
MXZ-4F83VFMXZ-5F102VFMXZ-6F122VF
Number Of Connectable Indoor Units2 - 42 - 52 - 6
Heat (Nominal)9.3 (3.4-11.6)10.5 (4.1-14.0)14.0 (3.5-16.5)
Cool (Nominal)8.3 (3.7-9.2)10.2 (3.9-11.0)12.2 (3.5-13.5)
Heat (UK)7.8 (2.82-9.63)8.7 (3.40-11.63)11.6 (2.90-13.71)
Cool (UK)8.2 (3.67-9.12)10.1 (3.86-10.90)12.1 (3.47-13.39)
COP / EER (Nominal)3.81 / 2.934.49 / 3.244.23 / 3.33
Scop / Seer (Bsen14825)4.2 / 6.34.20 / 6.63.59 (143.4%) / 7.52 (300.7%)
Erp Energy Efficiency CLASS Heat/CoolA++ / A++A++ / A++A++ / A++
Max Airflow (M3/Min) Heat/Cool64.9 / 55.767.6 / 55.777 / 63
Sound Pressure Level (Dba) Heat/Cool51 / 4956 / 5257 / 55
Sound Power Level (Dba) Cool616569
Dimensions (Mm) Width X Depth X Height950 x 330 x 796950 x 330 x 1048
Weight (Kg)626388
Electrical Supply220-240v, 50Hz
PhaseSingleSingleSingle
Power Input (Kw) Heat/Cool (Nominal)2.44 / 2.832.34 / 3.153.31 / 3.66
Power Input (Kw) Heat/Cool (UK)2.20 / 2.262.15 / 2.993.04 / 3.44
Starting Current (A)10.713.817.2
Running Current (A) Heat/Cool [Max]10.7 / 12.4 [20.4]12.7 / 17.2 [21.4]14.5 / 16.1 [30]
Interconnecting Cable No. Cores4 Core
Total Pipe Length (M)7080
Max Pipe Length Per Indoor Unit (M)25
Pre-Charged To (M)7080
Max Height Difference (M)15 (10 if OU higher than IU)
Charge Refrigerant (Kg)2.4
Co2 Equivalent (T) - R32 (Gwp 675)6.256.258.36
Max Additional Refrigerant (Kg)0.91.61

Compatible Indoor Units

Back to products
Add selected to wishlist