NEW PANASONIC AQUAREA T-CAP MONO-BLOC J GENERATION
32 For retrofit and new builds, Aquarea T-CAP is the ideal solution for those installations where the output capacity is demanding
AQUAREA T-CAP MONO-BLOC J GENERATION PROVIDES BOTH DOMESTIC HOT WATER AND HEAT FOR RADIATORS AND UNDERFLOOR HEATING FROM ONE OUTDOOR UNIT
Ideal to ensure that the heating capacity is maintained even at very low temperatures.
This line-up is able to maintain the heat pump output capacity until -20 °C outdoor temperature without the help of an electrical booster heater
Model Reference | Rated Heat Output (kW) | System COP | Min Flow Rate (l) | Electric Heater Cap (kW) | Fuse (Amps) | Electrical Supply |
||||
Outdoor Unit | A-7/W35 | A2 /W35 | A7/W35 | A-7/W35 | A2 /W35 | A7/W35 | A7/W35 | |||
WH-MXC09J3E5 | 9.00 | 9.00 | 9.00 | 3.08 | 3.81 | 5.08 | 25.80 | 3 | 30 / 30 | Single |
WH-MXC12J6E5 | 12.00 | 12.00 | 12.00 | 2.82 | 3.53 | 4.80 | 34.40 | 6 | 30 / 30 | Single |
WH-MXC09J6E8 | 9.00 | 9.00 | 9.00 | 3.08 | 3.81 | 5.08 | 25.80 | 3 | 20 / 16 | Three |
WH-MXC12J9E8 | 12.00 | 12.00 | 12.00 | 2.82 | 3.53 | 4.80 | 34.40 | 9 | 20 / 20 | Three |
WH-MXC16J9E8 | 16.00 | 16.00 | 16.00 | 2.39 | 3.10 | 4.52 | 45.80 | 9 | 20 / 20 | Three |
T-CAP stands for Total Capacity. This line-up is able to maintain the same nominal capacity even at -15°C without the help of an electrical booster heater. T-CAP is also able to provide extremely high efficiency, regardless of the outside temperature or the water temperature. The MXC adapts well in an existing installation with a boiler backup, and in a new application with underfloor heating, low temperature radiators or even fan-coil heaters. This range can also be connected to a solar kit in order to increase efficiency and minimise the impact on the ecosystem. Finally, it is possible to connect a thermostat for even better heating or cooling control and management.
Technical focus
Efficient control of room temperature based on the outdoor temperature, indoor temperature using the Aquarea Manager.
Optional Smartphone control
Range from 9 to 16kW, Single and Three Phase
Maximum hydraulic module output temperature: 55°C
Works at temperatures as low as -20°C
Cooling temperature range 5 ~ 20°C
Advanced Technical Data
Single Phase Models
Single Phase | Three Phase | ||||
Outdoor Unit | WH-MXC09H3E5 | WH-MXC12H6E5 | WH-MXC16H9E5 | ||
Heating capacity at +7°C (heating water at 35°C) | kW | 9,00 | 12,00 | 16,00 | |
COP at +7°C (heating water at 35°C) | W/W | 4,84 | 4,74 | 4,28 | |
Heating capacity at +2°C (heating water at 35°C) | kW | 9,00 | 12,00 | 16,00 | |
COP at +2°C (heating water at 35°C) | W/W | 3,59 | 3,44 | 3,10 | |
Heating capacity at -7°C (heating water at 35°C) | kW | 9,00 | 12,00 | 16,00 | |
COP at -7°C (heating water at 35°C) | W/W | 2,85 | 2,72 | 2,49 | |
Cooling capacity at 35°C (cooling water at 7°C) | kW | 7,00 | 10,00 | 12,20 | |
EER at 35°C (cooling water at 7°C) | W/W | 3,17 | 2,81 | 2,56 | |
Energy Efficiency Class at 35°C | A++ | A++ | A++ | A++ | |
Energy Efficiency Class at 55°C | A++ | A++ | A++ | A++ | |
Sound power level | Heating / Cooling | dB | 68 / 67 | 69 / 68 | 72 / 71 |
Dimensions | H x W x D | mm | 1.410 x 1.283 x 320 | 1.410 x 1.283 x 320 | 1.410 x 1.283 x 320 |
Weight | kg | 142 | 142 | 164 | |
Refrigerant (R410A)¹ | kg / TCO2 Eq. | 2,30 / 4,802 | 2,30 / 4,802 | 2,35 / 4,907 | |
Water pipe connector | R 1 | R 1 | R 1 | ||
Pump | Number of speeds | Variable Speed | |||
Input power (Min / Max) | W | 32 / 102 | 34 / 110 | 34 / 110 | |
Heating water flow (?T=5 K. 35°C) | l/min | 25,8 | 34,4 | 34,4 | |
Capacity of integrated electric heater | kW | 3 | 6 | 6 | |
Input Power | Heating | kW | 1,86 | 2,53 | 3,74 |
Cooling | kW | 2,21 | 3,56 | 4,76 | |
Running and Starting current | Heating | A | 8,8 | 11,7 | 5,7 |
Cooling | A | 10,4 | 16,5 | 7,1 | |
Current 1 | A | 29,0 | 29,0 | 15,5 | |
Current 2 | A | 13,0 | 26,0 | 13,0 | |
Recommended Fuse | A | 30 / 30 | 30 / 30 | 16 / 16 | |
Recommended cable size, supply 1 & 2 | mm² | 3 x 4,0 or 6,0 / 3 x 4,0 | 3 x 4,0 or 6,0 / 3 x 4,0 | 5 x 1,5 / 5 x 1,5 | |
Operation range | Outdoor ambient | °C | -20 ~ +35 | ||
Water outlet | Heating | °C | 20 ~ 60 | ||
Cooling | °C | 5 ~ 20 |