Redesigned Etherea 2016. Perfect outside, perfect inside.
WHITE MODEL (Inc. Infra Red Controller).
Optional Hardwired Controller CZ-RD514C and Wi-Fi Interface PA-AC-WIFI1 also available.
Model Reference | Nom. Cool (kW) | Nom. Heat (kW) | Max Pipe (m) | EuP Lot 10 Energy Rating | Fuse (Amps) | Pipe Size Gas | Pipe Size Liquid | Replace R22 | Electrical Supply |
||
Indoor Unit | Outdoor Unit | SCOP | SEER | ||||||||
CS-Z7SKEW-M | CU-Z7SKE | 2.05 | 2.80 | 15 | 4.70 | 7.50 | 16 | 3/8 | 1/4 | Yes | Single |
CS-Z9SKEW-M | CU-Z9SKE | 2.50 | 3.40 | 15 | 4.90 | 8.50 | 16 | 3/8 | 1/4 | Yes | Single |
CS-Z12SKEW-M | CU-Z12SKE | 3.50 | 4.00 | 15 | 4.90 | 8.50 | 16 | 3/8 | 1/4 | Yes | Single |
CS-Z15SKEW-M | CU-Z15SKE | 4.20 | 5.30 | 20 | 4.00 | 6.90 | 16 | 1/2 | 1/4 | Yes | Single |
CS-Z18SKEW-M | CU-Z18SKE | 5.00 | 5.80 | 20 | 4.40 | 7.30 | 16 | 1/2 | 1/4 | Yes | Single |
Product Description
Redesigned Etherea 2016. Perfect outside, perfect inside.
The new Etherea with Econavi intelligent sensor and new nanoe air-purifying system: outstanding efficiency (A+++), comfort (Super Quiet technology of only 19 dB(A)) combined with a breakthrough design.
We believe that going green should not compromise on comfort. This is why Panasonic is introducing the new Econavi system: combining a human detection sensor and control program technology to detect and reduce energy waste by up to 38% . The the new nanoe™ technology provides a cleaner living environment by purifying the air, as well as the surroundings. Together, these breakthrough technologies define what Panasonic’s Eco Clean Life Innovation is all about – innovations that improve the environment, whilst making life as comfortable as possible.
R32 – the most environmentally friendly refrigerant on the market. Compared to R22 and R410A, R32 has a very low potential impact on the depletion of ozone layer and global warming. European regulation CE 517/2014 makes the replacement of fluorinated gases (F-gases) compulsory, such as R410A, for environmental reasons. Panasonic’s commitment to innovation means leading the European R32 change, ahead of the 2017-2030 transition period for refrigerant changes, granted by the European regulation.
Econavi with intelligent eco sensors. 5 Features saving energy all at once Intelligent Sensors are able to detect potential energy waste by using the Human Activity Sensor and Sunlight Sensor, being able to monitor human location, movements, absence and sunlight intensity. It then automatically adjusts cooling power to save energy efficiently, with uninterrupted heating and cooling comfort and convenience.
New nano-sized electrostatic atomised water particles, nanoe™, that improve air quality Experiment proven benefits of electrostatic atomised water particles, nanoe™. The benefits range widely from inhibiting viruses and bacteria, inhibiting mould and allergens, providing moisturised skin. Experiments by universities and research institutions have proven the effects of nanoe™. The world is focusing its attention on this breakthrough technology that could be the key to air purification. nanoe™ is nano-sized electrostatic atomized water particles with plentiful OH radicals. Its effectiveness of bacteria inhibition depends on the number of OH radical, which is generated at the rate of 480 billion per second.
New Etherea performance: the very best SEER and SCOP available. Original Panasonic Inverter technology and a high performance compressor provide top-class operating efficiency.This materialises in lower electricity bills, whilst contributing to environmental protection.
Optional Internet Control. The Etherea Wi-Fi accessory offers the possibility of controlling the air conditioners remotely, by using a smartphone, tablet or PC connected to the internet. The Etherea accessory is wire-connected to the unit, giving full bidirectional connectivity and the ability to control power consumption, error code messages etc.
Features and Benefits
Product Images
Power and Wiring Information
All wiring on Panasonic RAC products is 3C+E Interconnecting. Power supply to Outdoor Unit unless specified.
Note that Power Supply can be fed to either Indoor or Outdoor unit.
Advanced Technical Data
Indoor Unit Technical Data | Model Number | ||||
CS-Z7SKEW(M) | CS-Z9SKEW(M) | CS-Z12SKEW(M) | CS-Z15SKEW(M) | CS-Z18SKEW(M) | |
Cooling (kW) - Nominal | 2.05 | 2.50 | 3.50 | 4.20 | 5.00 |
Heating (kW) - Nominal | 2.80 | 3.40 | 4.00 | 5.30 | 5.80 |
Cooling (kW) - UK Condition | 2.09 | 2.55 | 3.57 | 4.29 | 5.10 |
Heating (kW) - UK Condition | 2.90 | 3.62 | 4.20 | 4.93 | 5.43 |
Sensible Cooling Duty (UK) | 1.66 | 1.88 | 2.23 | 2.56 | 2.96 |
Sound Pressure - Cooling (dBA) | 19-37 | 19-39 | 19-42 | 25-35 | 34-44 |
Sound Pressure - Heating (dBA) | 19-28 | 19-40 | 19-42 | 29-42 | 34-44 |
Height (mm) | 295 | 295 | 295 | 295 | 295 |
Width (mm) | 919 | 919 | 919 | 919 | 919 |
Depth (mm) | 194 | 194 | 194 | 194 | 194 |
Weight (kG) | 9 | 9 | 10 | 10 | 10 |
Air Flow - Cooling (m³/min) | 5.05-11.13 | 4.85-11.77 | 4.83-12.48 | 5.98-12.68 | 8.17-12.72 |
Air Flow - Heating (m³/min) | 5.05-11.13 | 4.85-11.77 | 4.83-12.48 | 5.98-12.68 | 8.17-12.72 |
Outdoor Unit Technical Data | Model Number | ||||
CU-E7SKE | CURE9SKE | CU-E12SKE | CU-E15SKE | CU-E18SKE | |
Height (mm) | 542 | 542 | 619 | 619 | 695 |
Width (mm) | 780 | 780 | 824 | 824 | 875 |
Depth (mm) | 289 | 289 | 299 | 299 | 320 |
Weight (kG) | 30 | 33 | 35 | 35 | 46 |
Sound Pressure - Cooling (dBA) | 45 | 46 | 48 | 49 | 47 |
Sound Pressure - Heating (dBA) | 46 | 47 | 50 | 51 | 47 |
Liquid (mm(inches)) | 6.35 (1/4) | 6.35 (1/4) | 6.35 (1/4) | 6.35 (1/4) | 6.35 (1/4) |
Gas (mm(inches)) | 9.52 (3/8) | 9.52 (3/8) | 9.52 (3/8) | 12.7 (1/2) | 12.7 (1/2) |
Max Pipe Run | 15 | 15 | 15 | 20 | 20 |
Max Pipe Lift | 10 | 10 | 10 | 15 | 15 |
Pre-charged to (m) | 7.5 | 7.5 | 7.5 | 7.5 | 7.5 |
Standing Charge (kG) | 0.76 | 0.85 | 0.91 | 0.87 | 1.03 |
Additional g/m | 10 | 10 | 10 | 10 | 15 |
Refrigerant | R32 | ||||
Phase | Single | ||||
Power Supply to | Indoor or Outdoor (not both) | ||||
Start Current (A) | 2.8 | 3.3 | 4.4 | 6.4 | 7.6 |
Fuse Rating (A) | 16 | 16 | 16 | 20 | 25 |
Interconnecting | 3C + E | 3C + E | 3C + E | 3C + E | 3C + E |
System Power Input (Cool/Heat) - kW | 0.45 / 0.62 | 0.53 / 0.72 | 0.84 / 0.92 | 1.24 / 1.44 | 1.5 / 1.7 |