Panasonic Wall PACi Standard and Elite Inverter offers high heating capacity at -7°C. The unit’s compact design and flat face ensure discreet installation, even in a small space.
Model Reference | Nom. Cool (kW) | Nom. Heat (kW) | Max Pipe (m) | EuP Lot 10 Energy Rating | Fuse (Amps) In/Out | Pipe Size Gas | Pipe Size Liquid | Electrical Supply |
||
Indoor Unit | Outdoor Unit | SCOP | SEER | |||||||
S-36PK1E5A | U-36PE2E5A | 3.60 | 4.0 | 40 | 4.20 | 6.30 | 16 | 1/2 | 1/4 | Single |
S-50PK1E5A | U-50PE2E5A | 5.00 | 5.60 | 40 | 4.00 | 6.10 | 16 | 1/2 | 1/4 | Single |
S-60PK1E5A | U-60PE2E5A | 6.00 | 7.00 | 40 | 4.00 | 6.60 | 20 | 5/8 | 3/8 | Single |
S-71PK1E5A | U-71PE2E5A | 7.10 | 8.00 | 50 | 3.90 | 6.60 | 20 | 5/8 | 3/8 | Single |
S-100PK1E5A | U-100PE2E5A | 9.50 | 9.50 | 75 | 3.80 | 6.20 | 25 | 5/8 | 3/8 | Single |
S-71PK1E5A | U-71PE2E8A | 7.10 | 8.00 | 50 | 3.80 | 6.10 | 16 | 5/8 | 3/8 | Three |
S-100PK1E5A | U-100PE2E8A | 9.50 | 9.50 | 75 | 3.80 | 6.00 | 16 | 5/8 | 3/8 | Three |
Includes CZ-RTC4 Controller
Features and Benefits
Product Images
Power/Wiring
Panasonic PAC-i systems require a separate power supply to Indoor (3 Amp isolator for all units) and Outdoor Units. It is also possible to supply power to outdoor unit only, and run power to indoor via a 3 core flex from a field supplied fused terminal block. A separate 2 core 0.75mm² screened cable will also be required for data connection
Advanced Technical Data
Indoor Unit Technical Data | |||||
Model | S-36PK1E5A | S-50PK1E5A | S-60PK1E5A | S-71PK1E5A | S-100PK1E5A |
Cooling (kW) - Nominal | 3.60 | 5.00 | 6.00 | 7.10 | 9.50 |
Heating (kW) - Nominal | 4.00 | 5.60 | 7.00 | 8.00 | 9.50 |
Cooling (kW) - Max SEER Condition | 4.00 | 5.60 | 7.10 | 8.00 | 10.50 |
Heating (kW) - Max SCOP Avg Climate Condition | 5.00 | 6.50 | 8.00 | 9.00 | 11.50 |
Sensible Heat Ratio (SHR) | 2.60 | 4.10 | 5.60 | 5.90 | 6.70 |
Sound Pressure Level (dBA) | 35/31/27 | 40/36/32 | 47/44/40 | 47/44/40 | 49/45/41 |
Height - mm (grille) | 300 | ||||
Width - mm (grille) | 1065 | ||||
Depth - mm (grille) | 230 | ||||
Weight - kG (grille) | 13 | 13 | 14.5 | 14.5 | 14.5 |
Air Flow Rate (m³/min) | 11.0/9.5/7.5 | 14.0/12.0/10.5 | 18.0/14.5/11.5 | 18.0/14.5/11.5 | 19.0/16.5/13.0 |
Fused Spur (A) | 5 |
Outdoor Unit Technical Data | |||||||
Model | U-36PE2E5A | U-50PE2E5A | U-60PE2E5A | U-71PE1E5A | U-100PE1E58A | U-125PE1E58A | U-140PE1E58A |
Combinations | Single | Single | Single | Twin | Twin/Triple | Twin/Triple/Quad | Twin/Triple |
Height (mm) | 619 | 619 | 619 | 996 | 996 | 1416 | 1416 |
Width (mm) | 799 | 799 | 799 | 940 | 940 | 940 | 940 |
Depth (mm) | 299 | 299 | 299 | 340 | 340 | 340 | 340 |
Weight (kG) | 39 | 39 | 40 | 69 | 98 | 98 | 98 |
Airflow (m3/min) Cool/Heat | 38/38 | 38/41 | 38/41 | 60/60 | 110/95 | 130/110 | 135/120 |
Sound Pressure Cooling (dBA) | 45 | 46 | 46 | 48 | 52 | 53 | 54 |
Liquid (mm(inches)) | 6.35 (1/4) | 6.35 (1/4) | 9.52 (3/8) | 9.52 (3/8) | 9.52 (3/8) | 9.52 (3/8) | 9.52 (3/8) |
Gas (mm(inches)) | 12.7 (1/2) | 12.7 (1/2) | 15.88 (5/8) | 15.88 (5/8) | 15.88 (5/8) | 15.88 (5/8) | 15.88 (5/8) |
Max Pipe Run (m) | 40 | 40 | 40 | 50 | 75 | 75 | 75 |
Max Pipe Lift (m) | 30 | 30 | 30 | 30 | 30 | 30 | 30 |
Pre-charged to (m) | 30 | 30 | 30 | 30 | 30 | 30 | 30 |
Standing Charge (kG) | 1.4 | 1.4 | 1.95 | 2.35 | 3.4 | 3.4 | 3.4 |
Refrigerant | R410a | ||||||
Add Charge p/metre (g) | 30 | ||||||
Phase | Single | Single (Three) | |||||
Power Supply to | IU (5A) and OU or OU with feed to IU | ||||||
Max Current (A) | 11.00 | 12.00 | 16.50 | 18.00 | 25.00 (9.00) | 28.00 (10.00) | 30.00 (11.00) |
Run Current (A) | 3.60 | 5.95 | 8.15 | 8.25 | 9.70 (3.45) | 14.30 (5.00) | 18.60 (6.30) |
Fuse Rating (A) | 16 | 16 | 16 | 20 | 25 (16) | 32 (16) | 32 (16) |
Interconnecting | 2C Screen 0.75mm? |